Author: Lei, X.
Paper Title Page
MOP028 Field Integral Measurement System and Optical Alignment System for HUST THz-FEL 80
 
  • B. Qin, Q.S. Chen, M. Fan, Q. Fu, T. Hu, X. Lei, K.F. Liu, X. Liu, P. Tan, Y.Q. Xiong, J. Yang, L. Yang
    HUST, Wuhan, People's Republic of China
  • X. Liu, Z. Ouyang, Y.B. Wang
    Huazhong University of Science and Technology, State Key Laboratory of Advanced Electromagnetic Engineering and Technology,, Hubei, People's Republic of China
  • Y.J. Pei
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A Free Electron Laser oscillator with radiation wavelength 50–100 μm is under construction in Huazhong University of Science and Technology (HUST). The linear polarization undulator with K=1.0-1.25 has been designed and manufactured by Kyma s.r.l., by using a pure permanent magnet scheme. Acceptance test bas been performed in Kyma factory with well controlled phase error and field integrals for all gaps. This paper introduces the development of an online field integrals measurement system for the undulator, using the stretched wire method. The design and considerations of the optical alignment system is described as well.