Author: Sukhanov, A.I.
Paper Title Page
WEPLM66 Microphonics Studies at STC in Fermilab 743
 
  • C. Contreras-Martinez
    FRIB, East Lansing, Michigan, USA
  • Y.M. Pischalnikov, W. Schappert, A.I. Sukhanov, J.C. Yun
    Fermilab, Batavia, Illinois, USA
 
  The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-WEPLM66  
About • paper received ※ 28 August 2019       paper accepted ※ 31 August 2019       issue date ※ 08 October 2019  