Author: Neveu, N.R.
Paper Title Page
TUYBA3 Benchmarking the LCLS-II Photoinjector 301
 
  • N.R. Neveu, T.J. Maxwell, C.E. Mayes
    SLAC, Menlo Park, California, USA
 
  Funding: DOE Contract No. DE-AC02-76SF00515
Commissioning of the LCLS-II photoinjector started in late 2018. Efforts to accurately model the gun and laser profiles is ongoing. Simulations of the photoinjector and solenoid are performed in ASTRA, IMPACT-T and OPAL-T. This work includes efforts to use the laser profile at the virtual cathode as the initial transverse beam distribution, and effects of 2D and 3D field maps. Beam size results are compared to experimental measurements taken at the YAG screen located after the gun.
 
slides icon Slides TUYBA3 [1.320 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-TUYBA3  
About • paper received ※ 29 August 2019       paper accepted ※ 05 September 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)