Author: Xu, Zh.H.
Paper Title Page
TUPAL003 Measurement of the Injection Beam Parameters by the Multi-Wire Scanner for CSNS 1014
 
  • M.Y. Huang, H.C. Liu, S. Wang, Zh.H. Xu, P. Zhu
    IHEP, Beijing, People's Republic of China
  • X.H. Lu
    CSNS, Guangdong Province, People's Republic of China
 
  In order to inject the H beam to the Rapid Cycling Synchrotron (RCS) with high precision and high transport efficiency, the injection beam parameters need to be measured and then corrected while its eccentric position or direction angle is too large. In this paper, firstly, a method to measure the injection beam parameters by using two of the four multi-wire scanners (MWSs) is presented. The injection commissioning results confirmed that this method works well. Secondly, a method to measure the signals of injection beam and circular beam by the INMWS02 is presented and the method work well during the beam commissioning.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)