TUPMF032 | RF Conceptual Design of Normal Conducting Cavity for an eRHIC Rapid Cycling Synchrotron | 1316 |
|
||
Funding: Work is supported by Brookhaven Science Associates, LLC under contract No. DE-AC02-98CH10886 with the US DOE. The Rapid Cycling Synchrotron (RCS) for the eRHIC Ring-Ring design will provide on energy injection (up to 18 GeV) of high charge, polarized electron bunches to the eRHIC electron storage ring. The RF system comprises a large number of 563MHz fundamental cavities, providing up to 45MV per turn. The cavities will operate in pulsed mode with <20% duty factor, at a repetition rate of 1 Hz. In this paper we report the conceptual RF design of the cavity. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF032 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPMF034 | Measuring the Electrical Center and Field Flatness of 704 MHz Deflecting Cavity for LEReC with Wire Stretching System | 1320 |
|
||
Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy. 704 MHz deflecting cavity was designed for the Low Energy RHIC electron Cooling (LEReC) project. The cavity will serve as a major component in diagnostic line. In LEReC project the requirement on the energy spread of the electron beam is extremely high (better than 10-4) and the diagnostic system has to to be designed accordingly. The 704 MHz transverse deflecting cavity provides the vertical kick to the beam after it passes through the dispersion dipole so that we can measure the energy spread of the core of the bunch. Traditional way of determining the electrical center of the cavity involves the needle pulling and integration of the signal which is prone to the cumulative error. We present the measurement result from a wire stretching system that is much more efficient and accurate compared to the bead/needle pulling method. Both simulation and experimental results are shown in this paper and the potential in further application is discussed at the end. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF034 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPML095 | Improvement of Wire-Stretching Technique to the RF Measurements of E-Center and Multipole Field for the Dipole Cavities | 4885 |
|
||
Funding: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. After the first publication* of wire-stretching technique from its principle to measure the electrical center of a deflecting cavity, more refinements of this techniques including the review of its analytical and simulation results, RF circuit improvement to improve the signal to noise ratio and its application to other cavities have been developed. These applications include the electrical center measurements for the LHC RFD and DQW crabbing cavity prototypes, multi-frequency harmonic kicker cavity for JLEIC electron cooler**, TE011 cavity developed for the beam magnetization measurement***, and a separator cavity at BNL****. Further development of measurement calibration, error reduction, alignment of cavity installation to the machine beam line, and multipole field analysis for the beam dynamics will be presented. *H. Wang, Proceedings of NAPAC2016, pp225-228 **S. A. Overstreet, BS Thesis 2017, Guilford College, Greensboro, NC ***J. Guo et al. these proceedings ****T. Xin et al, these proceedings |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML095 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |