Paper | Title | Page |
---|---|---|
WEPAF035 | Coherent Diffraction Radiation Imaging as an RMS Bunch Length Monitor | 1895 |
|
||
Funding: This work was supported by the EU under Grant Agreement No. 624890 and the STFC Cockcroft Institute core Grant No. ST/G008248/1. High-resolution bunch length measurement is of the utmost importance for current and future generations of light sources and linacs. It is also key to the optimisation of the final beam quality in plasma-based acceleration. We present progress in the development of a novel RMS bunch length monitor based on imaging the coherent diffraction radiation (CDR) produced by a non-invasive circular aperture. Due to the bunch lengths involved, the radiation produced is in the THz range. This has led to the development of a novel THz imaging system, which can be applied to low energy electron beams. For high energy beams the imaging system can be used as a single shot technique. Simulation results show that the profile of a CDR image of a beam is sensitive to bunch length and can thus be used as a diagnostic. The associated benefits of this imaging distribution methodology over the typical angular distribution measurement are discussed. Plans for experiments conducted at the SwissFEL (PSI, Switzerland), along with plans for future high energy single shot measurements are also presented. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF035 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAF036 | Energy Independence in Optical Transition Radiation Imaging | 1898 |
|
||
Funding: This work was supported by the EU under Grant Agreement No. 624890 and the STFC Cockcroft Institute core Grant No. ST/G008248/1. The exploitation of optical transition radiation (OTR) in imaging-based diagnostics for charged particle beams is a well-established technique. Simulations of the expected OTR transverse beam profiles are therefore important in both the design of such imaging systems and the analysis of the data. Simulating OTR images is relatively straightforward for low energy electron beams. However, in the near future electron machines will be using high-energy and low-emittance beams. Using such parameters can be challenging to simulate, and can be limiting in their account of practical factors, e.g. chromatic aberrations. In this work we show systematically that the use of low-energy parameters in high-energy OTR image simulations induces little deviation in the resulting transverse beam profiles. Simulations therefore become much easier to perform, and further analysis may be performed. This opens up exciting opportunities to perform simulations quicker and with reduced demands on the computation requirements. It will be shown in this contribution how this approach will enable enhanced ways to optimize OTR diagnostics. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF036 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPAK140 | Pyroelectric Detection of Coherent Radiation on the CLARA Phase 1 Beamline | 3577 |
SUSPF077 | use link to see paper's listing under its alternate paper code | |
|
||
The impacts of coherent synchrotron radiation (CSR) and space charge in the bunch compressor section of the CLARA Free Electron Laser (FEL) are expected to be significant, given the relatively high charge and short bunch lengths expected. The General Particle Tracer (GPT) code allows for the modelling of these effects in tandem, presenting an opportunity to more reliably estimate their effects on the CLARA beam. To provide confidence in future studies using GPT, a benchmarking study on the CLARA Phase 1 beamline is presented alongside relevant simulations. This study will make use of pyroelectric detectors to measure the emitted coherent power of the CLARA beam as it passes through a dispersive section whilst varying the chirp imparted on the bunches longitudinal phase space (LPS). Simulations presented demonstrate the viability of such a study, with energies between ∼ 10-100 nJ per pulse expected to be incident upon the detector face. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK140 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |