Author: Wawrzyniak, A.I.
Paper Title Page
THPAL107 Three Years of Operational Experience With the Solaris Vacuum System 3888
 
  • A.M. Marendziak, M. Rozwadowski, T. Sobol, M.J. Stankiewicz, A.I. Wawrzyniak
    Solaris National Synchrotron Radiation Centre, Jagiellonian University, Kraków, Poland
 
  Solaris, a 1.5 GeV third generation synchrotron light source, was commissioned in 2016 April and is currently operated in decay mode. Two beamlines PEEM/XAS and UARPES were installed and now are being commis-sioned. Three more PHELIX, XMCD and diagnostic beamlines have received funding and will be installed and commissioned in next few years. With total accumu-lated beam dose near to 690 A.h and three orders of mag-nitude reduction of outgassing the design goal of 500 mA beam current and electron energy of 1.5 GeV has been achieved. As the beam current was increased, a few vacu-um problems were encountered, including vacuum leaks in RF and arc sectors and unexpected pressure bursts near photon absorbers. Lessons learned and operational expe-rience will be presented and discussed in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL107  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL108 In-Situ Characterization of Normal Conducting RF Cavities in Solaris Light Source Storage Ring 3891
 
  • P.B. Borowiec, A.I. Wawrzyniak
    Solaris National Synchrotron Radiation Centre, Jagiellonian University, Kraków, Poland
  • J. Björklund Svensson
    Lund University, Division of Atomic Physics, Lund, Sweden
 
  The SOLARIS 1.5 GeV storage ring is equipped with two 100 MHz active cavities and two 3rd harmonic passive cavities. They are in operation since 2015. For control of their respective working points, knowledge about cavity voltage and higher order mode (HOM) frequency spec-trum is mandatory. After their installation in the storage ring and connection of the RF feeder to a high power isolator and a transmitter, the influence of the external elements on the quality factor and the HOM spectrum should be verified with respect to simulations of a simpli-fied model of a stand-alone cavity. This paper will pre-sent results of in-situ cavity measurements to qualify the HOM placement and their quality factor. HOM meas-urements have been performed in the range 100 MHz to 1.3 GHz for active cavities and 300 MHz to 1.5 GHz for 3rd harmonic cavities at three different temperatures under ultra-high vacuum conditions for each cavity separately. The measurement and analysis methodology will also be presented  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL108  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)