Research on Magnetic Center Measurement of Quadrupole and Sextupole Using Vibrating Wire Alignment Technique in HEPS-TF |
2860 |
|
- L. Wu, C. H. Li, H. Qu, H. Wang, X.L. Wang
IHEP, Beijing, People's Republic of China
- H.Y. Zhu
Institute of High Energy Physics (IHEP), People's Republic of China
|
|
|
In order to meet the extremely low emittance re-quirement, the magnets in the storage ring of High Energy Photon Source(HEPS) need to have a stable support and precise positioning. Vibrating wire align-ment technique can be used to pre-align the quadru-poles and sextupoles on one girder with high preci-sion. Research of vibrating wire alignment technique is one important project of HEPS Test Facility (HEPS-TF). In HEPS-TF, the key and difficult technologies of HEPS should be researched and developed. This paper introduces the principle of the vibrating wire align-ment technique and the measurement system in brief. The magnetic center measurement of quadrupole and sextupole using vibrating wire will be introduced in detail. It concludes the measurement procedure, mag-netic field distribution, measurement repeatability, sag correction and magnet adjustment measurement. The research of vibrating wire has get a better precision than the aim. The magnetic center measurement preci-sion reach to ±3μm and the magnet adjustment error is less than 6μm.
|
|