Author: Wang, Q.
Paper Title Page
THPML111 Test of the Tune Measurement System Based on BBQ at HLS-II Storage Ring 4926
 
  • L.T. Huang, F.L. Gao, P. Lu, B.G. Sun, H.Q. Wang, J.G. Wang, Q. Wang, F.F. Wu, Y.L. Yang, T.Y. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Supported by the National Science Foundation of China (Grant No. 11705203, 11575181)
The HLS-II storage ring is a crucial part of Hefei Light Source. Tune is one of the most important parameters of the electron storage ring, of which the tune measurement system is an integral component. In this paper, the design of a new tune measurement system based on BBQ (base band tune), is presented. Some experiments are performed to test this system. The new system is compared with the original system and the TBT (turn-by-turn) method respectively. The obtained results illustrate higher accuracy and higher stability for the new system. A new approach of calculating the betatron oscillation amplitude is proposed, and the betatron oscillation amplitudes in the normal running stage for the HLS-II storage ring are estimated at 95 nm (horizontal) and 60 nm (vertical).
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML111  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPML113 Design and Simulation of the Waveguide Coupler for the Cavity Beam Monitor 4932
 
  • Q. Wang, Q. Luo, B.G. Sun, F.F. Wu, Y.L. Yang, Z.R. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
  • Y.W. Wu
    USTC, Hefei, Anhui, People's Republic of China
 
  Funding: Supported by The National Key Research and Development Program of China (2016YFA0401900), NSFC (11375178, 11575181) and the Fundamental Research Funds for the Central Universities (WK2310000046)
The waveguide coupling is an important way to extract the signals of the specific eigenmodes required. The design of the waveguide coupler, including the waveguide-to-coaxial adapter behind it for the cavity bunch length monitor is presented. The influence of the dimension parameters is analyzed, which offers the theoretical support for the design and application of cavity bunch length monitor or cavity beam position monitor (CBPM). A series simulation based on CST is performed to verify the feasibility, and the simulation results show good performance.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML113  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)