Author: Takeuchi, Y.
Paper Title Page
WEPAL033 Development of Real-Time Mass Analysis System with Permanent Magnet for Ion Beam 2236
SUSPL051   use link to see paper's listing under its alternate paper code  
 
  • Y. Takeuchi, Y. Iwashita, H. Tongu
    Kyoto ICR, Uji, Kyoto, Japan
 
  In order to analyze time variation of the ion species in a pulse, we are developing a mass analysis system that has multiple collector electrodes to detect several ion species simultaneously. Strong permanent magnets can generate 1T magnetic field and the size of the analyzing magnet system can be compact. The detected signals are scanned by a fast multiplexer. The scanning rate is 2 MHz, so that all electrode signals of the 16 channels are scanned in 8 μs period. In this paper, details of the design of the analysis system, and preliminary beam extraction test results with prototype of the system are described.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL033  