Author: Stapleton, J.C.
Paper Title Page
THPML093 New Fast Kicker Results from the Muon g-2 E-989 Experiment at Fermilab 4879
 
  • A.P. Schreckenberger
    The University of Texas at Austin, Austin, Texas, USA
  • D. Barak, C.C. Jensen, G.E. Krafczyk, R.L. Madrak, H. Nguyen, H. Pfeffer, M. Popovic, J.C. Stapleton, C. Stoughton
    Fermilab, Batavia, Illinois, USA
  • A.T. Chapelain, A.A. Mikhailichenko, D. L. Rubin
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • N.S. Froemming
    CENPA, Seattle, Washington, USA
  • J.L. Holzbauer
    UMiss, University, Mississippi, USA
  • A.I. Keshavarzi
    The University of Liverpool, Liverpool, United Kingdom
 
  We describe the installation, commissioning, and characterization of the injection kicker system for the E-989 experiment at Fermilab for a precision measurement of the muon anomalous magnetic moment. Control and monitoring systems have been implemented to acquire and record the waveforms of each kicker pulse, and measurements of various kicker system observables were recorded in the presence of the 1.45 T g-2 storage ring magnetic field. These monitoring systems are necessary to understand the systematic contribution to the measurement of the precession frequency. We examine the dependence of muon capture to kicker field predictions.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML093  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)