  Solaris, a 1.5 GeV third generation synchrotron light source, was commissioned in 2016 April and is currently operated in decay mode. Two beamlines PEEM/XAS and UARPES were installed and now are being commis-sioned. Three more PHELIX, XMCD and diagnostic beamlines have received funding and will be installed and commissioned in next few years. With total accumu-lated beam dose near to 690 A.h and three orders of mag-nitude reduction of outgassing the design goal of 500 mA beam current and electron energy of 1.5 GeV has been achieved. As the beam current was increased, a few vacu-um problems were encountered, including vacuum leaks in RF and arc sectors and unexpected pressure bursts near photon absorbers. Lessons learned and operational expe-rience will be presented and discussed in this paper.  