Author: Sounas, A.
Paper Title Page
WEPAF080 Beam Size Measurements Based on Movable Quadrupolar Pick-ups 2028
 
  • A. Sounas, M. Gąsior, T. Lefèvre, A. Mereghetti, J. Olexa, S. Redaelli, G. Valentino
    CERN, Geneva, Switzerland
 
  Measurements with quadrupolar pick-ups (PU) have attracted particular interest as non-intercepting diagnostics for determining the transverse beam size. They are based on processing the signals of an electromagnetic PU for the extraction of the second-order moment, which contains information about the beam size. Despite the simplicity of the concept, quadrupololar measurements have always been highly challenging in reality. This comes from the fact that the quadrupolar moment constitutes only a very small part of the total PU signal dominated by the intensity and the position signals. Therefore, the beam size information can easily be lost due to small imperfections in the signal processing chain, such as asymmetries in the electronics and cables. In this paper, we present a new method for quadrupolar measurements using movable PUs. Through position and aperture scans, our technique minimizes the parasitic beam position signal and takes into account imperfections of the PU, cables and electronics, thus enabling an efficient auto-calibration of the measurement system. Preliminary studies, using collimators with embedded electrostatic PUs in the LHC at CERN, have shown very promising results.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF080  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)