Paper |
Title |
Page |
MOPMF047 |
Transverse Coupling Measurements With High Intensity Beams Using Driven Oscillations |
208 |
|
- T. Persson, G. Baud, X. Buffat, J.M. Coello de Portugal, E. Fol, K. Fuchsberger, M. Gabriel, M. Gąsior, M. Giovannozzi, G.H. Hemelsoet, M. Hostettler, M. Hruska, D. Jacquet, E.H. Maclean, L. Malina, J. Olexa, P.K. Skowroński, M. Solfaroli Camillocci, M.E. Söderén, R. Tomás, D. Valuch, A. Wegscheider, J. Wenninger
CERN, Geneva, Switzerland
|
|
|
Transverse coupling has been linked to instabilities and reduction in dynamic aperture and is hence a crucial parameter to control in the LHC. In this article we describe the development to use driven oscillations to measure the transverse coupling with high intensity beams. The method relies on the use of the transverse damper to drive an oscillation in a similar way as with an AC-dipole. The calculation of the coupling is based on the turn-by-turn data from all available BPMs gated for the excited bunch.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-MOPMF047
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAF045 |
Performance Optimisation of Turn-by-Turn Beam Position Monitor Data Harmonic Analysis |
3064 |
|
- L. Malina, J.M. Coello de Portugal, J. Dilly, P.K. Skowroński, R. Tomás, M.S. Toplis
CERN, Geneva, Switzerland
- J.M. Coello de Portugal
UPC, Barcelona, Spain
|
|
|
Nowadays, turn-by-turn beam position monitor data is increasingly utilized in many accelerators, as it allows for fast and simultaneous measurement of various optics parameters. The accurate harmonic analysis of turn-by-turn data costs beam time when needed online. Generally, the electronic noise is avoided by cleaning of the data based on singular value decomposition. In this paper, we exploit the cleaning procedure to compress the data for the harmonic analysis. This way the harmonic analysis is sped up by an order of magnitude. The impact on measurement accuracy is discussed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPAF045
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPMF014 |
First Experiments at the CLEAR User Facility |
4066 |
|
- R. Corsini, A. Curcio, S. Curt, S. Döbert, W. Farabolini, D. Gamba, R. Garcia Alia, T. Lefèvre, G. McMonagle, P.K. Skowroński, M. Tali, F. Tecker
CERN, Geneva, Switzerland
- E. Adli, C.A. Lindstrøm, K.N. Sjobak
University of Oslo, Oslo, Norway
- R.M. Jones, A. Lagzda
UMAN, Manchester, United Kingdom
|
|
|
The new "CERN Linear Electron Accelerator for Research" (CLEAR) facility at CERN started its operation in fall 2017. CLEAR results from the conversion of the CALIFES beam line of the former CLIC Test Facility (CTF3) into a new testbed for general accelerator R&D and component studies for existing and possible future accelerator applications. CLEAR can provide a stable and reliable electron beam from 60 to 220 MeV in single or multi bunch configuration at 1.5 GHz. The experimental program includes studies for high gradient acceleration methods, e.g. for CLIC X-band and plasma technology, prototyping and validation of accelerator components, e.g. for the HL-LHC upgrade, and irradiation test capabilities for characterization of electronic components and for medical applications. An overview of the facility capabilities and a summary of the latest results will be presented.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPMF014
|
|