Paper |
Title |
Page |
THPAL092 |
Test Particle Monte Carlo Simulation of NEG Coated Narrow Tubular Samples |
3862 |
|
- O. Seify, A.N. Hannah, O.B. Malyshev, Sirvinskaite, R. Sirvinskaite, R. Valizadeh
STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
- Sirvinskaite, R. Sirvinskaite
Loughborough University, Loughborough, Leicestershire, United Kingdom
|
|
|
The pumping properties of the NEG coated vacuum chambers play an important role in the efficiency of vac-uum system of accelerators. The sticking probability of the NEG films is one the most important parameters to characterise the pumping properties of the NEG coated vacuum chambers. In order to investigate the NEG film sticking probability, Test Particle Monte-Carlo (TPMC) models were used. The models were based on the design of the installed experimental setup in ASTeC Vacuum Science group laboratory at Daresbury Laboratory (DL). The results of the simulations have been used for inter-preting the results of the measurements in the experi-mental setup.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL092
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAL098 |
Pumping Properties of Single Metal Zirconium Non-Evaporable Getter Coating |
3869 |
|
- Sirvinskaite, R. Sirvinskaite, M.D. Cropper, M.D. Cropper
Loughborough University, Leicestershre, United Kingdom
- A.N. Hannah, O.B. Malyshev, R. Valizadeh
STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
- O.B. Malyshev, R. Valizadeh
Cockcroft Institute, Warrington, Cheshire, United Kingdom
|
|
|
Non-evaporable getter (NEG) coating has been used for years in many particle accelerator facilities due to its evenly distributed pumping speed, low thermal outgassing, and low photon and electron stimulated desorption yields. We have previously demonstrated that quaternary Ti-Zr-Hf-V coating deposited from an alloy wire has the lowest desorption yields, the highest sticking probability and sorption capacity. In this work, we explore the single element targets which are widely available and can be produced in a form of a wire that is easy to apply for a uniform coating of various shapes of vacuum chamber. Single metal Zr coatings have been tested to find a more efficient and cheaper way of producing the NEG-coated vacuum chambers. Two samples coated with Zr of dense and columnar structure were analysed and results of the pumping properties are reported. The results show that pure Zr coating could be an economic solution, despite not being as effective as can be achieved with quaternary NEG film. It shows that columnar Zr coating can be activated and reaches full pumping capacity at 160°C. This is close to the activation temperature of Ti-Zr-Hf-V and lower than that for the widely used ternary Ti-Zr-V alloy.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL098
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|