Author: Sangroula, M.P.
Paper Title Page
THPAK005 Measuring the Coupling Impedance of Vacuum Components for the Advanced Photon Source Upgrade Using a Goubau Line 3211
SUSPF074   use link to see paper's listing under its alternate paper code  
 
  • M.P. Sangroula
    IIT, Chicago, Illinois, USA
  • R.M. Lill, R.R. Lindberg, R.B. Zabel
    ANL, Argonne, Illinois, USA
 
  The Planned upgrade of the Advanced Photon Source to a multi-bend achromat (MBA) will increase the x-ray brightness by two to three orders of magnitude. Storing such an intense beam stably inside the narrow gap vacuum chambers requires sophisticated and appropriately designed rf-components that helps to minimize rf heating and collective instabilities associated with the impedance of these small-aperture vacuum components. As part of this effort, my research focuses on impedance measurement and simulation of various MBA vacuum components. In this paper, we briefly introduce the novel Goubau line (G-line) test fixture for the impedance measurement, at first, and then present our measurements data along with simulations with simulations for various vacuum components designed for the APS Upgrade.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK005  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)