Author: Pribyl, L.
Paper Title Page
THPAF033 Degradation of Electron Beam Quality for a Compact Laser-Based FEL 3029
 
  • A.Y. Molodozhentsev, L. Pribyl
    Czech Republic Academy of Sciences, Institute of Physics, Prague, Czech Republic
  • K.O. Kruchinin
    ELI-BEAMS, Prague, Czech Republic
 
  Laser wake field acceleration (LWFA) mechanism allows to produce extremely short electron bunches of a few fs length with the energy up to a few GeV in extremely compact geometries providing unique electron beam parameters, in particular, transverse beam emittance (order of 1pi mm mrad), extremely short bunch length and high beam charge (up to 100pC) . This novel acceleration method therefore opens a new way to develop compact 'laser-based' FELs. In the frame of this report we analyze effects, which lead to degradation of an electron beam quality. The chromatic and collective effects are analyzed for a compact dedicated electron beam line to transport the electron beam to an undulator. In addition, the SASE FEL performance has been discussed taking into consideration the degradation of the electron beam quality.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAF033  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAF057 Electron Beam Diagnostics Concept for the ELI LUX Project 1954
 
  • K.O. Kruchinin, D. Kocon, A.Y. Molodozhentsev, L. Pribyl
    ELI-BEAMS, Prague, Czech Republic
  • A. Lyapin
    JAI, Egham, Surrey, United Kingdom
 
  Nowadays the popularity of Laser Wakefield Accelerators (LWFA) is increasingly growing. Although the quality of the beams produced by LWFA is still lower than provided by conventional accelerators, they have great potential to be considered as a new basis for future FELs and even colliders. Laser Undulator X-ray (LUX) source is being commissioned at ELI-beamlines in Czech Republic. The goal of this machine is to provide photon beam in so called "water window" wavelength region for user experiments. Possible upgrade of the facility towards the LWFA based FEL is also considered. The electron beam diagnostics is absolutely crucial for achieving the aim of LUX. Specific properties of the beam produced by current LWFA, such as low charge, poor beam stability, big beam divergence and energy spread, require rethinking and adaptation of the conventional diagnostic tools and, in some cases, development of new ones. Ideally, they have to be compact, stable, non-invasive and allow measurements in single-shot mode. In this report we will present an overview and design considerations for the LUX electron beam main diagnostics. We will also discuss the hardware status and future plans.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)