Author: Prazeres, R.
Paper Title Page
TUPML079 A Start to End Simulation of the Laser Plasma Wakefield Acceleration Experiment at ESCULAP 1731
SUSPF043   use link to see paper's listing under its alternate paper code  
 
  • K. Wang, C. Bruni, K. Cassou, V. Chaumat, N. Delerue, D. Douillet, S. Jenzer, V. Kubytskyi, P. Lepercq, H. Purwar
    LAL, Orsay, France
  • E. Baynard, M. Pittman
    CLUPS, Orsay, France
  • J. Demailly, O. Guilbaud, S. Kazamias, B. Lucas, G. Maynard, O. Neveu, D. Ros
    CNRS LPGP Univ Paris Sud, Orsay, France
  • D. Garzella
    CEA, Gif-sur-Yvette, France
  • R. Prazeres
    CLIO/ELISE/LCP, Orsay, France
 
  We present a start to end (s2e) simulation of the Laserplasma Wake Field Accelerator (LPWA) foreseen as the ESCULAP project. We use a photo injector to produce a 5 MeV 10 pC electron bunch with a duration of 1 ps RMS, it is boosted to 10 MeV by a S-band cavity and then compressed to 74 fs RMS (30 fs FWHM) by a magnetic compression chicane (dogleg). After the dogleg, a quadrupole doublet and a triplet are utilized to match the Twiss parameters before injecting into the subsequent plasma wakefield. A 40 TW laser is used to excite plasma wakefield in the 10 cm plasma cell. An optimized configuration has been determined yielding at the plasma exit an electron beam at 180 MeV with energy spread of 4.2%, an angular divergence of 0.6 mrad and a duration of 4 fs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPML079  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAL034 Bunch Length Measurements Using Coherent Smith-Purcell Radiation With Several Gratings at CLIO 2239
 
  • N. Delerue, S. Jenzer, V. Khodnevych, A. Migayron
    LAL, Orsay, France
  • J.P. Berthet, N. Jestin, J.-M. Ortega, R. Prazeres
    CLIO/ELISE/LCP, Orsay, France
 
  Funding: Financially supported by the Université Paris-Sud (programme "attractivité"), by the French ANR (contract ANR-12-JS05-0003-01) and by IN2P3.
Coherent Smith Purcell radiation allows the measurement of a beam longitudinal profile through the study of the emission spectrum of the radiation emitted when a grating is brought close from the beam. In order to increase the dynamic range of our measurements we have used several gratings and we report on the measured bunch form factor using this technique. We report on these measurements and on the background rejection used.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)