Paper |
Title |
Page |
WEPAL012 |
Measurements with the ELI-NP Cavity Beam Position Monitor Read-out Electronics at FLASH |
2169 |
|
- G. Franzini, D. Pellegrini, M. Serio, A. Stella, A. Variola
INFN/LNF, Frascati (Roma), Italy
- B.B. Baricevic, M. Cargnelutti
I-Tech, Solkan, Slovenia
- D. Lipka
DESY, Hamburg, Germany
- M. Marongiu
INFN-Roma, Roma, Italy
- A. Mostacci
Sapienza University of Rome, Rome, Italy
|
|
|
The Extreme Light Infrastructure - Nuclear Physics Gamma Beam Source (ELI-NP GBS) will be installed and commissioned starting within the next year in Magurele, Romania. It will generate gamma beam through Compton back-scattering of a recirculated laser and a multi-bunch electron beam, produced by a 720 MeV LINAC. In order to obtain bunch by bunch position measurements, four cavity beam position monitors (cBPM) near the two interaction points are foreseen. Extensive tests on the cBPM read-out electronics, recently developed by Instrumentation Technologies and acquired for ELI-NP GBS, were performed in laboratory at INFN-LNF and at FLASH in DESY, during the user operation. In the latter case, three cBPMs installed along the LINAC, with similar features as the ones of ELI-NP GBS, were used as measuring devices and signal sources for the read-out electronics under test. We present here the measurements collected and the related analysis, with a particular focus on the beam position measurement resolution.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL012
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAK020 |
Optics Model and Measurements of the DAΦNE Transfer Lines |
3249 |
|
- O.R. Blanco-García, A. De Santis, G. Di Pirro, C. Milardi, D. Pellegrini, A. Stecchi, A. Stella
INFN/LNF, Frascati (Roma), Italy
|
|
|
The different components of the DAΦNE accelerator complex: LINAC, Damping Ring and two colliding rings are connected by a composite system of Transfer Lines which, thanks to adaptive configurations, are able to transport electron and positron beams at 510~MeV. Recently, thanks to the introduction of new diagnostics tools, the optics model of the DAΦNE Transfer Lines has been improved and succesfully used to make the collider operations more efficient. The measurements done by using the new tools and their impact on the optics model optimization process are presented and discussed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK020
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|