Author: Pacey, T.H.
Paper Title Page
WEPAF035 Coherent Diffraction Radiation Imaging as an RMS Bunch Length Monitor 1895
 
  • J. Wolfenden, R.B. Fiorito, C.P. Welsch
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • R.B. Fiorito, C.P. Welsch, J. Wolfenden
    The University of Liverpool, Liverpool, United Kingdom
  • T.H. Pacey, T.H. Pacey
    UMAN, Manchester, United Kingdom
  • A.G. Shkvarunets
    UMD, College Park, Maryland, USA
 
  Funding: This work was supported by the EU under Grant Agreement No. 624890 and the STFC Cockcroft Institute core Grant No. ST/G008248/1.
High-resolution bunch length measurement is of the utmost importance for current and future generations of light sources and linacs. It is also key to the optimisation of the final beam quality in plasma-based acceleration. We present progress in the development of a novel RMS bunch length monitor based on imaging the coherent diffraction radiation (CDR) produced by a non-invasive circular aperture. Due to the bunch lengths involved, the radiation produced is in the THz range. This has led to the development of a novel THz imaging system, which can be applied to low energy electron beams. For high energy beams the imaging system can be used as a single shot technique. Simulation results show that the profile of a CDR image of a beam is sensitive to bunch length and can thus be used as a diagnostic. The associated benefits of this imaging distribution methodology over the typical angular distribution measurement are discussed. Plans for experiments conducted at the SwissFEL (PSI, Switzerland), along with plans for future high energy single shot measurements are also presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF035  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAK140 Pyroelectric Detection of Coherent Radiation on the CLARA Phase 1 Beamline 3577
SUSPF077   use link to see paper's listing under its alternate paper code  
 
  • B.S. Kyle
    University of Manchester, Manchester, United Kingdom
  • R.B. Appleby, T.H. Pacey
    UMAN, Manchester, United Kingdom
  • P.H. Williams
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • J. Wolfenden
    The University of Liverpool, Liverpool, United Kingdom
 
  The impacts of coherent synchrotron radiation (CSR) and space charge in the bunch compressor section of the CLARA Free Electron Laser (FEL) are expected to be significant, given the relatively high charge and short bunch lengths expected. The General Particle Tracer (GPT) code allows for the modelling of these effects in tandem, presenting an opportunity to more reliably estimate their effects on the CLARA beam. To provide confidence in future studies using GPT, a benchmarking study on the CLARA Phase 1 beamline is presented alongside relevant simulations. This study will make use of pyroelectric detectors to measure the emitted coherent power of the CLARA beam as it passes through a dispersive section whilst varying the chirp imparted on the bunches longitudinal phase space (LPS). Simulations presented demonstrate the viability of such a study, with energies between ∼ 10-100 nJ per pulse expected to be incident upon the detector face.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK140  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)