Author: Overstreet, A.
Paper Title Page
THPML095 Improvement of Wire-Stretching Technique to the RF Measurements of E-Center and Multipole Field for the Dipole Cavities 4885
 
  • G.-T. Park, J. Guo, H. Wang
    JLab, Newport News, Virginia, USA
  • A. Overstreet
    ODU, Norfolk, Virginia, USA
  • B. P. Xiao, T. Xin
    BNL, Upton, Long Island, New York, USA
 
  Funding: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.
After the first publication* of wire-stretching technique from its principle to measure the electrical center of a deflecting cavity, more refinements of this techniques including the review of its analytical and simulation results, RF circuit improvement to improve the signal to noise ratio and its application to other cavities have been developed. These applications include the electrical center measurements for the LHC RFD and DQW crabbing cavity prototypes, multi-frequency harmonic kicker cavity for JLEIC electron cooler**, TE011 cavity developed for the beam magnetization measurement***, and a separator cavity at BNL****. Further development of measurement calibration, error reduction, alignment of cavity installation to the machine beam line, and multipole field analysis for the beam dynamics will be presented.
*H. Wang, Proceedings of NAPAC2016, pp225-228
**S. A. Overstreet, BS Thesis 2017, Guilford College, Greensboro, NC
***J. Guo et al. these proceedings
****T. Xin et al, these proceedings
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML095  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)