Author: Novokshonov, A.I.
Paper Title Page
TUPMF068 Beam Dynamics on a Coupling Resonance at PETRA III 1417
 
  • I.V. Agapov, J. Keil, G. Kube, G.K. Sahoo, R. Wanzenberg
    DESY, Hamburg, Germany
  • Y.-C. Chae
    ANL, Argonne, Illinois, USA
  • A.I. Novokshonov
    TPU, Tomsk, Russia
 
  Working on a coupling resonance is a usual way of producing round beams in a synchrotron. The beam dynamics in this regime is however more complicated, and the emittance is sensitive to the working point, coupling correction, and bunch current drop with time, which complicates the operation. We present experience with optics setup for working on a coupling resonance in PETRA III, including linear and nonlinear beam optics characteristics, and the measurement of the horizontal and vertical beam emittances with a 2D interferometer. Beam dynamics on a coupling resonance for PETRA IV, the MBA upgrade of PETRA III currently under consideration, is also presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF068  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPMF072 Microwave Instability and Energy Spread Measurement via Vertical Dispersion Bump in PETRA III 1427
 
  • Y.-C. Chae, D. Dzhingaev, M. Ebert, G. Falkenberg, J. Keil, G. Kube, G.K. Sahoo, M. Sprung, R. Wanzenberg, F. Westermeier
    DESY, Hamburg, Germany
  • A.I. Novokshonov
    TPU, Tomsk, Russia
 
  The recent measurement of bunch length versus current indicated that the longitudinal impedance (Z/n) is 0.15 Ω in close agreement with the impedance model*. Naive application of Keil-Schnell criteria predicts the threshold of microwave instability at 0.25 mA. Since the single bunch intensity is in the range of 0.2-2.5 mA depending on the fill-pattern of PETRA III, we expect to observe the fill-pattern dependent energy spread according to the theory. However, the 3rd generation light sources comparable to PETRA III often reported the observation which was much greater than the theoretical one. In order to induce the beam size variation we had used skew quadrupoles to generate the dispersion in vertical plane. In particular we made dispersion bump at the undulator sector so that we were able to use the X-ray optics for the precise determination of small vertical beam size. In this paper we report the experimental setup and measurement data with the estimate on the instability threshold. We also report the vertical emittance and energy spread based on the X-ray beam size measurement as well as the RF signal which was excited by the beam at the longitudinal feedback cavity.
* K. Balewski, R. Wanzenberg, "OBSERVATION OF INTENSITY DEPENDENT SINGLE BUNCH EFFECTS AT THE SYNCHROTRON LIGHT SOURCE PETRA III", Proc. of IPAC2011, p. 730.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF072  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)