Author: Nakazato, Y.
Paper Title Page
THPMK147 Measurement of Slice-Emittance of Electron Bunch Using RF Transverse Deflector 4648
 
  • T. Sasaki, Y. Nakazato, M. Washio
    Waseda University, Tokyo, Japan
  • Y. Koshiba
    RISE, Tokyo, Japan
  • K. Sakaue
    Waseda University, Waseda Institute for Advanced Study, Tokyo, Japan
 
  We have been studying a compact electron accelerator based on an S-band Cs-Te photocathode rf electron gun at Waseda University. We are applying this high quality electron beam to soft X-ray generation, coherent THz wave generation and pulse radiolysis experiment. In these applications, longitudinal parameters of the electron beam are important. Thus, we developed the RF deflecting cavity which can directly convert longitudinal distribution of the beam to transverse with high temporal resolution, and succeeded in measuring longitudinal profile of an electron beam from the RF gun. Encouraged by these successful results, we started to measure slice emittance. Slice emittance would be very useful for improving the RF electron gun cavity. Therefore, we tried to measure the slice emittance of the electron beam by applying the Q-scan method to deflected beam by RF deflecting cavity. In this conference, we will report the principle, experimental results of the slice emittance measurement, and future prospects.
C. Vaccarezza et al., "Slice emittance measurements at SPARC photoinjector with a RF deflector", Proc. of EPAC08, Genoa, Italy
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPMK147  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)