Author: Mazzoni, S.
Paper Title Page
WEPAF034 A Supersonic Gas Jet-Based Beam Profile Monitor Using Fluorescence for HL-LHC 1891
 
  • H.D. Zhang, A.S. Alexandrova, R. Schnuerer, C.P. Welsch
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • M. Ady, E. Barrios Diaz, N. Chritin, O.R. Jones, R. Kersevan, T. Marriott-Dodington, S. Mazzoni, A. Rossi, G. Schneider, R. Veness
    CERN, Geneva, Switzerland
  • A.S. Alexandrova, A. Salehilashkajani, R. Schnuerer, C.P. Welsch, H.D. Zhang
    The University of Liverpool, Liverpool, United Kingdom
  • P. Forck, S. Udrea
    GSI, Darmstadt, Germany
  • P. Smakulski
    WRUT, Wroclaw, Poland
 
  Funding: The HL-LHC project, the Helmholtz Association under contract VH-NG-328, the EU's 7th Framework Programme under grant agreement no 215080 and the STFC Cockcroft core grant No. ST/G008248/1.
The High-Luminosity Large Hadron Collider (HL-LHC) project aims to increase the machine luminosity by a factor of 10 as compared to the LHC's design value. To achieve this goal, a special type of electron lens is being developed. It uses a hollow electron beam which co-propagates with the hadron beam to act on any halo particles without perturbing the core of the beam. The overlapping of both beams should be carefully monitored. This contribution presents the design principle and detailed characteristics of a new supersonic gas jet-based beam profile monitor. In contrast to earlier monitors, it relies on fluorescence light emitted by the gas molecules in the jet following interaction with the primary hadron beams. A dedicated prototype has been designed and built at the Cockcroft Institute and is being commissioned. Details about monitor integration, achievable resolution and dynamic range will be given.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAF070 Commissioning of Beam Instrumentation at the CERN AWAKE Facility After Integration of the Electron Beam Line 1993
 
  • I. Gorgisyan, C. Bracco, S. Burger, S. Döbert, S.J. Gessner, E. Gschwendtner, L.K. Jensen, S. Jensen, S. Mazzoni, D. Medina, K. Pepitone, L. Søby, F.M. Velotti, M. Wendt
    CERN, Geneva, Switzerland
  • M. Cascella, S. Jolly, F. Keeble, M. Wing
    UCL, London, United Kingdom
  • V.A. Verzilov
    TRIUMF, Vancouver, Canada
 
  The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) is a project at CERN aiming to accelerate an electron bunch in a plasma wakefield driven by a proton bunch*. The plasma is induced in a 10 m long Rubidium vapour cell using a pulsed Ti:Sapphire laser, with the wakefield formed by a proton bunch from the CERN SPS. A 16 MeV electron bunch is simultaneously injected into the plasma cell to be accelerated by the wakefield to energies in GeV range over this short distance. After successful runs with the proton and laser beams, the electron beam line was installed and commissioned at the end of 2017 to produce and inject a suitable electron bunch into the plasma cell. To achieve the goals of the experiment, it is important to have reliable beam instrumentation measuring the various parameters of the proton, electron and laser beams such as transverse position, transverse profile as well as temporal synchronization. This contribution presents the status of the beam instrumentation in AWAKE, including the new instruments incorporated into the system for measurements with the electron beam line, and reports on the performance achieved during the AWAKE runs in 2017.
* Gschwendtner E., et al. "AWAKE, the Advanced Proton Driven Plasma Wakefield Experiment at CERN", NIM A 829 (2016)76-82
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF070  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAF074 Non-invasive Beam Diagnostics with Cherenkov Diffraction Radiation 2005
 
  • T. Lefèvre, M. Bergamaschi, O.R. Jones, R. Kieffer, S. Mazzoni
    CERN, Geneva, Switzerland
  • L.Y. Bartnik, M.G. Billing, Y.B.P. Bordlemay Padilla, J.V. Conway, M.J. Forster, J.P. Shanks, S. Wang
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • M. Bergamaschi, P. Karataev
    Royal Holloway, University of London, Surrey, United Kingdom
  • V.V. Bleko, A.S. Konkov, J.S. Markova, A. Potylitsyn
    TPU, Tomsk, Russia
  • L. Bobb
    DLS, Oxfordshire, United Kingdom
  • K. Lekomtsev
    JAI, Egham, Surrey, United Kingdom
 
  Based on recent measurements of incoherent Cherenkov Diffraction Radiation (ChDR) performed on the Cornell Electron Storage Ring, we present here a concept for the centering of charged particle beams when passing close to dielectric material. This would find applications as beam instrumentation in dielectric capillary tubes, typically used in novel accelerating technologies, as well as in collimators using bent crystals for high-energy, high-intensity hadron beams, such as the Large Hadron Collid-er or Future Circular Collider. As a charged particle beam travels at a distance of a few mm or less from the surface of a dielectric material, incoherent ChDR is produced inside the dielectric. The photons are emitted at a large and well-defined angle that allows their detection with a limited contribution of background light. A set of ChDR detectors distributed around a dielectric would enable both the beam position and tilt angle to be measured with a good resolution.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF074  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPML118 The AWAKE Electron Spectrometer 4947
 
  • F. Keeble, M. Cascella, J. A. Chappell, L.C. Deacon, S. Jolly, M. Wing
    UCL, London, United Kingdom
  • I. Gorgisyan, S. Mazzoni
    CERN, Geneva, Switzerland
  • P.L. Penna, M. Quattri
    ESO, Garching bei Muenchen, Germany
 
  The AWAKE experiment at CERN aims to use a proton driven plasma wakefield to accelerate electrons from 10–20 MeV up to GeV energies in a 10 m plasma cell. We present the design of the magnetic spectrometer which will measure the electron energy distribution. Results from the calibration of the spectrometer's scintillator and optical system are presented, along with a study of the backgrounds generated by the 400 GeV SPS proton beam.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPML118  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)