Paper |
Title |
Page |
WEPML073 |
Research on Magnetic Center Measurement of Quadrupole and Sextupole Using Vibrating Wire Alignment Technique in HEPS-TF |
2860 |
|
- L. Wu, C. H. Li, H. Qu, H. Wang, X.L. Wang
IHEP, Beijing, People's Republic of China
- H.Y. Zhu
Institute of High Energy Physics (IHEP), People's Republic of China
|
|
|
In order to meet the extremely low emittance re-quirement, the magnets in the storage ring of High Energy Photon Source(HEPS) need to have a stable support and precise positioning. Vibrating wire align-ment technique can be used to pre-align the quadru-poles and sextupoles on one girder with high preci-sion. Research of vibrating wire alignment technique is one important project of HEPS Test Facility (HEPS-TF). In HEPS-TF, the key and difficult technologies of HEPS should be researched and developed. This paper introduces the principle of the vibrating wire align-ment technique and the measurement system in brief. The magnetic center measurement of quadrupole and sextupole using vibrating wire will be introduced in detail. It concludes the measurement procedure, mag-netic field distribution, measurement repeatability, sag correction and magnet adjustment measurement. The research of vibrating wire has get a better precision than the aim. The magnetic center measurement preci-sion reach to ±3μm and the magnet adjustment error is less than 6μm.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPML073
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPML075 |
Test of Magnet Girder Prototypes for HEPS-TF |
2863 |
|
- H. Wang, C. H. Li, S.J. Li, J. Liu, H. Qu, Z. Wang, L. Wu
IHEP, Beijing, People's Republic of China
- H.Y. Zhu
Institute of High Energy Physics (IHEP), People's Republic of China
|
|
|
Auto-tuning magnet girder is one of the key technolo-gies to be solved for HEPS-TF (Test Facility of High Ener-gy Photon Source). The girder should have high adjusting accuracy, high stability and can be beam-based aligned, to obtain the stability requirements of beam orbit. There are two girders developed, and the tests have been done. The accuracy of girder motion is within 10 microns while the adjusting range is 1 mm and the resolution is better than 1 microns, the natural frequency is higher than 24 Hz.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPML075
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|