A Combined Temperature and Magnetic Field Mapping System for SRF Cavities |
1228 |
|
- J.M. Köszegi, K. Alomari, J. Knobloch, O. Kugeler, B. Schmitz
HZB, Berlin, Germany
|
|
|
In the past decade, a significant improvement of SRF cavity performance has been achieved, yet a number of performance limiting mechanisms, such as magnetic flux trapping, still exist. We present a diagnostics tool which combines flux expulsion measurement during the superconducting phase transition with temperature mapping during operation. This system has a time resolution for both temperature and magnetic field mapping of 2 ms for full cavity coverage, so that short-lived events, including cavity quenches, can easily be resolved.
|
|
|