Paper | Title | Page |
---|---|---|
MOZGBD4 |
Toward 10 fs Timing Stability of PAL-XFEL | |
|
||
PAL-XFEL demonstrates 20 fs jitter in e-bunch arrival time at the end of undulators and its pump-probe system, which is extremely useful for maintaining high stability of machine and time-resolved experiments with high time resolution. Our low phase noise timing system and high stability high power RF system enable this low jitter. Our measurement shows 10 fs jitter of e-bunch arrival time at the injector and it increased ~20 fs due to e-bunch energy variation. The possibility of improving the final jitter is described based on the optimization of bunch compressors and longitudinal feedback. | ||
![]() |
Slides MOZGBD4 [14.381 MB] | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPMK033 | PAL-XFEL Linac RF System Status | 4369 |
|
||
Funding: Ministry of Science and ICT The PAL-XFEL Linear Accelerator began user support in March 2017 after one year of RF conditioning in 2016. The energy jitter was 0.013% when operating the H-X linear accelerator with 46 modulators, Klystron, LLRF, SSA and vacuum system at 6.838 GeV energy during user support period. So far, we have replaced four klystrons and 10 thyratron switches. We also measured the influence of temperature changes of RF components according to repetition rates of the machine. We will report on the measurement results of this operating experience and performance. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPMK033 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |