Paper | Title | Page |
---|---|---|
WEPAF067 | Alignment and Monitoring Systems for Accelerators and Experiments Based on BCAM - First Results and Benefits of Systems Developed for ATLAS, LHCb and HIE-ISOLDE | 1983 |
|
||
In the last few years alignment and monitoring systems based on BCAM* cameras active sensors, or their HBCAM evolution, have been developed at the request of the Technical Coordination of LHC experiments and HIE-ISOLDE facility Project Leader. ADEPO (ATLAS DEtector POsition) has been designed to speed up the precise closure - 0.3 mm - of large detector parts representing in total ~2500 tons. For LHCb a system has been studied and installed to monitor the positions of the Inner Tracker stations during the LHCb dipole magnet cycles. The MATHILDE (Monitoring and Alignment Tracking for HIE-ISOLDE) system has been developed to fulfil the alignment and monitoring needs for components of the LINAC enclosed in successive Cryo-Modules. These systems have been in each case configured and adapted to the objectives and environmental conditions: low space for integration; presence of magnetic fields; exposure to non-standard environmental conditions such as high vacuum and cryogenic temperatures. After a short description of the different systems and of the environmental constraints, this paper summarizes their first results, performances and their added value.
* BCAM: Brandeis CCD Angle Monitor, http://alignment.hep.brandeis.edu/Devices/BCAM/ |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF067 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAF082 | A Systematic Analysis of the Prompt Dose Distribution at the Large Hadron Collider | 2036 |
|
||
During the operation of the Large Hadron Collider (LHC) the continuous particle losses create a mixed particle radiation field in the LHC tunnel and the adjacent caverns. Exposed electronics and accelerator components show dose dependent accelerated aging effects. In order to achieve an optimal lifetime associated to radiation damage, the position of the equipment is chosen in dependency of the amplitude of the radiation fields. Based on the continuous analysis of the data from more than 3900 ionisation chamber beam loss monitors the evolution of the radiation levels is monitored during the accelerator operation. Normalising the radiation fields with either the integrated luminosity or the integrated intensities allows extrapolating the radiation levels of future accelerator operation. In this paper, the general radiation levels in the arcs and the insertion regions at the LHC and their evolution will be presented. The changes in the prompt dose distribution along the LHC between the operation in 2016 and 2017 will be discussed. The impact of different accelerator settings on the local dose distribution will be addressed as well. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF082 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAF083 | Distributed Optical Fiber Radiation Sensing at CERN | 2039 |
|
||
The CERN's accelerator tunnels are associated with very complex mixed field radiation environments. Radiation degrades electronic components and directly affects their lifetimes causing failures that contribute to the machine downtime periods. In our contribution, we will report on the development and first employment of a Distributed Optical Fiber Radiation Sensor (DOFRS) at CERN. The most interesting feature of DOFRS technology is to provide an online and spatially distributed map of the dose levels in large machines with spatial resolution of the order of one meter. This fiber based dose sensor will provide valuable information in addition to the currently installed active and passive dosimeters. After demonstrating the working principle of DOFRS*, the first operational prototype was installed in the Proton Synchrotron Booster during last 2016/17 end-of-the-year technical stop. The DOFRS has been acquiring data successfully since the beginning of 2017 operations. The performances that were achieved by the first prototype will be discussed in the final contribution. The DOFRS measurements will also be bench-marked to the results provided by other punctual dosimeters.
*I. Toccafondo et al., 'Distributed Optical Fiber Radiation Sensing in a Mixed-Field Radiation Environment at CERN,' J. Lightw. Technol. 35, 3303, 3310, 2017. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF083 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |