Author: Johnson, W.
Paper Title Page
TUPMF034 Measuring the Electrical Center and Field Flatness of 704 MHz Deflecting Cavity for LEReC with Wire Stretching System 1320
 
  • T. Xin, J.M. Brennan, J.C.B. Brutus, K. Mernick, K.S. Smith, B. P. Xiao, A. Zaltsman
    BNL, Upton, Long Island, New York, USA
  • W. Johnson
    SBU, Stony Brook, New York, USA
  • H. Wang
    JLab, Newport News, Virginia, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
704 MHz deflecting cavity was designed for the Low Energy RHIC electron Cooling (LEReC) project. The cavity will serve as a major component in diagnostic line. In LEReC project the requirement on the energy spread of the electron beam is extremely high (better than 10-4) and the diagnostic system has to to be designed accordingly. The 704 MHz transverse deflecting cavity provides the vertical kick to the beam after it passes through the dispersion dipole so that we can measure the energy spread of the core of the bunch. Traditional way of determining the electrical center of the cavity involves the needle pulling and integration of the signal which is prone to the cumulative error. We present the measurement result from a wire stretching system that is much more efficient and accurate compared to the bead/needle pulling method. Both simulation and experimental results are shown in this paper and the potential in further application is discussed at the end.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)