Author: Han, J.F.
Paper Title Page
THPAK097 Ion Optic Design of the Microprobe System at Sichuan University 3460
 
  • Z. Li, Z. An, J.F. Han, G.Q. Zheng
    SCU, Chengdu, People's Republic of China
 
  Funding: Supported by the National Natural Science Foundation of China (11375122, 11511140277)
At the end of 2016, the first beam was extracted from the 3.0 MV Tandetron accelerator system at Sichuan University, China. The accelerator is imported from the HVEE as a multi-purpose research platform. For one of the main applications, the system will be connected to a micro-beamline to achieve submicron resolution, so the accelerator is designed with energy stability as high as 0.01%. The measured brightness for 3 MeV proton beam is 5.06 pA/um2mrad2MeV and the energy stability is reached the goal of design. The ion optic design of the microprobe beam line will be presented in this paper.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK097  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)