Paper |
Title |
Page |
MOPMF047 |
Transverse Coupling Measurements With High Intensity Beams Using Driven Oscillations |
208 |
|
- T. Persson, G. Baud, X. Buffat, J.M. Coello de Portugal, E. Fol, K. Fuchsberger, M. Gabriel, M. Gąsior, M. Giovannozzi, G.H. Hemelsoet, M. Hostettler, M. Hruska, D. Jacquet, E.H. Maclean, L. Malina, J. Olexa, P.K. Skowroński, M. Solfaroli Camillocci, M.E. Söderén, R. Tomás, D. Valuch, A. Wegscheider, J. Wenninger
CERN, Geneva, Switzerland
|
|
|
Transverse coupling has been linked to instabilities and reduction in dynamic aperture and is hence a crucial parameter to control in the LHC. In this article we describe the development to use driven oscillations to measure the transverse coupling with high intensity beams. The method relies on the use of the transverse damper to drive an oscillation in a similar way as with an AC-dipole. The calculation of the coupling is based on the turn-by-turn data from all available BPMs gated for the excited bunch.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-MOPMF047
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPAF024 |
Impedance and Instability Studies in LEIR with Xenon |
720 |
|
- N. Biancacci, H. Bartosik, M. Gąsior, S. Hirlaender, V. Kain, T.E. Levens, E. Métral
CERN, Geneva, Switzerland
- M. Migliorati
Rome University La Sapienza, Roma, Italy
|
|
|
In 2017, the LEIR accelerator has been operated with Xe39+ beam for fixed target experiments in the SPS North Area. The different ion species, with respect to the usually operated Pb54+, allowed for additional comparative measurements of tune shift versus intensity at injection energy both in coasting and bunched beams. The fast transverse instability observed for high accumulated intensities has been as well characterized and additional observations relevant to impedance have been collected from longitudinal Schottky signal and BTF measurements. The results of these measurements are summarised and compared to the currently developed machine impedance model.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAF024
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPAF080 |
Beam Size Measurements Based on Movable Quadrupolar Pick-ups |
2028 |
|
- A. Sounas, M. Gąsior, T. Lefèvre, A. Mereghetti, J. Olexa, S. Redaelli, G. Valentino
CERN, Geneva, Switzerland
|
|
|
Measurements with quadrupolar pick-ups (PU) have attracted particular interest as non-intercepting diagnostics for determining the transverse beam size. They are based on processing the signals of an electromagnetic PU for the extraction of the second-order moment, which contains information about the beam size. Despite the simplicity of the concept, quadrupololar measurements have always been highly challenging in reality. This comes from the fact that the quadrupolar moment constitutes only a very small part of the total PU signal dominated by the intensity and the position signals. Therefore, the beam size information can easily be lost due to small imperfections in the signal processing chain, such as asymmetries in the electronics and cables. In this paper, we present a new method for quadrupolar measurements using movable PUs. Through position and aperture scans, our technique minimizes the parasitic beam position signal and takes into account imperfections of the PU, cables and electronics, thus enabling an efficient auto-calibration of the measurement system. Preliminary studies, using collimators with embedded electrostatic PUs in the LHC at CERN, have shown very promising results.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF080
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPAF084 |
Commissioning the ELENA Beam Diagnostics Systems at CERN |
2043 |
|
- G. Tranquille, S. Burger, M. Gąsior, P. Grandemange, T.E. Levens, O. Marqversen, L. Søby
CERN, Geneva, Switzerland
|
|
|
The Extra Low ENergy Antiproton ring (ELENA) at CERN entered the commissioning phase in November 2016 using H− ions and antiprotons to setup the machine at the different energy plateaus. The low intensities and energy of the ELENA beam generate very weak signals making beam diagnostics very challenging. With a circulating beam current of less than 1 μA and an energy where the beam annihilates in less than a few microns of matter, special care was taken during the design phase to ensure an optimal performance of these measurement devices once installed on the ring and transfer lines. A year on we present the performance of the various devices that have been deployed to measure the beam parameters from the extraction point of the Antiproton Decelerator (AD), through the ELENA ring and in the experimental lines.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF084
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|