The number of turns is an important parameter for the tuning of a cyclotron; it is even more important for high intensity machines such as the 1.4 MW High Intensity Proton Accelerator (HIPA) facility. Up to recently, the number of turns had to be measured using radial probes, which cannot be performed during user operation but only during beam development shifts. For user shifts, the estimate of the number of turns was based on the acceleration voltage measurements, with the inherent limited precision of RF measurements. A new scheme based on the time of flight (ToF) measurements has been deployed on the two cyclotrons of HIPA. It is based on the cross-correlation of fast sampled data from pickups located at the entrance and at the exit of the cyclotrons. For the first cyclotron, called Injector 2 (accelerating the beam from 870 keV to 72MeV), the beam had to be externally modulated whereas, for the Ring Cyclotron (72 MeV to 590 MeV), no external modulation was necessary. This paper will present the details of both implementations, their limitations and the quality of the results that can be obtained with the ToF techniques.
|
|