Paper |
Title |
Page |
THPMK085 |
Development of a Pre-Injector Test Bench for Future SLRI Light Source |
4499 |
|
- K. Kittimanapun, Ch. Dhammatong, N. Juntong, W. Phacheerak, M. Phanak
SLRI, Nakhon Ratchasima, Thailand
|
|
|
A pre-injector test bench at the Synchrotron Light Research Institute (SLRI) is under development as one of the preparations for the future SLRI light source and of choices for the possible upgrade of the current injector. The pre-injector test bench includes a pulsed thermionic gun, a fast pulse deflector, a buncher and a pre-buncher. The thermionic electron gun with a cathode made of a single crystal CeB6 is employed as an electron emitter providing small emittance and uniform electron density. The fast pulse deflector shorten the extracted electrons of a few microseconds to that of a few nanoseconds. The electron pulses are further bunched by both the 238 MHz pre-buncher and the 476 MHz buncher to allow the 1-MeV electron beam. The experimental setups for emittance and beam profile measurements are installed on a movable diagnostic stand which is, later on, replaced by the beam bunching devices. The designs of the test bench will be discussed in this paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPMK085
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPMK088 |
Low Emittance Thermionic Electron Gun at SLRI |
4509 |
|
- K. Kittimanapun, Ch. Dhammatong, N. Juntong, W. Phacheerak, M. Phanak
SLRI, Nakhon Ratchasima, Thailand
|
|
|
The Synchrotron Light Research Institute (SLRI) has developed a new thermionic electron gun producing low emittance electron beam for the future upgrade of the existing one. The thermionic cathode made of a CeB6 single crystal is selected due to its properties providing high electron beam current, uniform current density, and high resistance to contamination. In addition, the CeB6 cathode of 3 mm in diameter can produce up to a few Amperes of electron beam current. The electron gun is pulsed at 500 kV with a few microseconds wide to avoid high voltage breakdown as well as to reduce space charge effect resulting in the emittance growth of the extracted electron beam. The preliminary simulation and design of the electron gun together with the high voltage system are described in the paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPMK088
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|