Author: Denz, R.
Paper Title Page
WEPAF081 An Enhanced Quench Detection System for Main Quadrupole Magnets in the Large Hadron Collider 2032
 
  • J. Spasic, D.O. Calcoen, R. Denz, V. Froidbise, S. Georgakakis, T. Podzorny, A.P. Siemko, J. Steckert
    CERN, Geneva, Switzerland
 
  To further improve the performance and reliability of the quench detection system (QDS) for main quadrupole magnets in the Large Hadron Collider (LHC), there is a planned upgrade of the system during the long shutdown period of the LHC in 2019-2020. While improving the already existing functionalities of quench detection for quadrupole magnets and field-bus data acquisition, the enhanced QDS will incorporate new functionalities to strengthen and improve the system operation and maintenance. The new functionalities comprise quench heater supervision, interlock loop monitoring, power cycling possibility for the whole QDS and its data acquisition part, monitoring and synchronization of trigger signals, and monitoring of power supplies. In addition, the system will have two redundant power supply feeds. Given that the enhanced QDS units will replace the existing QDS units in the LHC tunnel, the units will be exposed to elevated levels of ionizing radiation. Therefore, it is necessary to design a radiation tolerant detection system. In this work, an overview of the design solution for such enhanced QDS is presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF081  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMG006 Experimental Setup to Characterize the Radiation Hardness of Cryogenic Bypass Diodes for the HL-LHC Inner Triplet Circuits 2620
 
  • A. Will, G. D'Angelo, R. Denz, M.F. Favre, D. Hagedorn, G. Kirby, T. Koettig, A. Monteuuis, F. Rodriguez-Mateos, A.P. Siemko, K. Stachon, M. Valette, A.P. Verweij, D. Wollmann
    CERN, Geneva, Switzerland
  • A. Bernhard, A.-S. Müller
    KIT, Karlsruhe, Germany
  • L. Kistrup
    KEA, Copenhagen, Denmark
 
  Funding: Work supported by the Wolfgang Gentner Programme of the German Federal Ministry of Education and Research
For the high luminosity upgrade of the Large Hadron Collider (LHC), it is planned to replace the existing triplet quadrupole magnets with Nb3Sn quadrupole magnets, which provide a comparable integrated field gradient with a significantly increased aperture. These magnets will be powered through a novel superconducting link based on MgB2 cables. One option for the powering layout of this triplet circuit is the use of cryogenic bypass diodes, where the diodes are located inside an extension to the magnet cryostat and operated in superfluid helium. Hence, they are exposed to radiation. For this reason the radiation hardness of existing LHC type bypass diodes and more radiation tolerant prototype diodes needs to be tested up to the radiation doses expected at their planned position during their lifetime. A first irradiation test is planned in CERN's CHARM facility starting in spring 2018. Therefore, a cryo-cooler based cryostat to irradiate and test LHC type diodes in-situ has been designed and constructed. This paper will describe the properties of the sample diodes, the experimental roadmap and the setup installed in CHARM. Finally, the first measurement results will be discussed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPMG006  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)