- Sirvinskaite, R. Sirvinskaite, M.D. Cropper, M.D. Cropper
Loughborough University, Leicestershre, United Kingdom
- A.N. Hannah, O.B. Malyshev, R. Valizadeh
STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
- O.B. Malyshev, R. Valizadeh
Cockcroft Institute, Warrington, Cheshire, United Kingdom
|
|
|
Non-evaporable getter (NEG) coating has been used for years in many particle accelerator facilities due to its evenly distributed pumping speed, low thermal outgassing, and low photon and electron stimulated desorption yields. We have previously demonstrated that quaternary Ti-Zr-Hf-V coating deposited from an alloy wire has the lowest desorption yields, the highest sticking probability and sorption capacity. In this work, we explore the single element targets which are widely available and can be produced in a form of a wire that is easy to apply for a uniform coating of various shapes of vacuum chamber. Single metal Zr coatings have been tested to find a more efficient and cheaper way of producing the NEG-coated vacuum chambers. Two samples coated with Zr of dense and columnar structure were analysed and results of the pumping properties are reported. The results show that pure Zr coating could be an economic solution, despite not being as effective as can be achieved with quaternary NEG film. It shows that columnar Zr coating can be activated and reaches full pumping capacity at 160°C. This is close to the activation temperature of Ti-Zr-Hf-V and lower than that for the widely used ternary Ti-Zr-V alloy.
|
|