Author: Cianchi, A.
Paper Title Page
TUXGBE3 Status of Plasma-Based Experiments at the SPARC_LAB Test Facility 603
 
  • E. Chiadroni, D. Alesini, M.P. Anania, M. Bellaveglia, A. Biagioni, F.G. Bisesto, E. Brentegani, F. Cardelli, G. Costa, M. Croia, D. Di Giovenale, G. Di Pirro, M. Ferrario, F. Filippi, A. Gallo, A. Giribono, A. Marocchino, L. Piersanti, R. Pompili, S. Romeo, J. Scifo, V. Shpakov, A. Stella, C. Vaccarezza, F. Villa
    INFN/LNF, Frascati (Roma), Italy
  • A. Cianchi
    INFN-Roma II, Roma, Italy
  • M. Marongiu, A. Mostacci
    Sapienza University of Rome, Rome, Italy
  • J.B. Rosenzweig
    UCLA, Los Angeles, California, USA
  • A.R. Rossi
    Istituto Nazionale di Fisica Nucleare, Milano, Italy
  • A. Zigler
    The Hebrew University of Jerusalem, The Racah Institute of Physics, Jerusalem, Israel
 
  The current activity of the SPARC LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. The current status of such an activity is presented, together with results related to the applicability of plasmas as focusing lenses in view of a complete plasma-based focusing, accelerating and extraction system.  
slides icon Slides TUXGBE3 [10.258 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUXGBE3  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPML050 A Massive Open Online Course on Particle Accelerators 512
 
  • N. Delerue, A. Faus-Golfe
    LAL, Orsay, France
  • M.E. Biagini
    INFN/LNF, Frascati (Roma), Italy
  • E. Bründermann, A.-S. Müller
    KIT, Eggenstein-Leopoldshafen, Germany
  • P. Burrows
    JAI, Oxford, United Kingdom
  • G. Burt
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • A. Cianchi
    Università di Roma II Tor Vergata, Roma, Italy
  • C. Darve, R.A. Yogi
    ESS, Lund, Sweden
  • V.V. Dmitriyeva, S.M. Polozov
    MEPhI, Moscow, Russia
  • J. Kvissberg
    Lund University, Lund, Sweden
  • P. Lebrun
    JUAS, Archamps, France
  • E. Métral, H. Schmickler, J. Toes
    CERN, Geneva, Switzerland
  • S.P. Møller
    ISA, Aarhus, Denmark
  • L. Rinolfi
    ESI, Archamps, France
  • A. Simonsson
    Stockholm University, Stockholm, Sweden
  • V.G. Vaccaro
    Naples University Federico II and INFN, Napoli, Italy
 
  Funding: European Union H2020 - ARIES Project
The TIARA (Test Infrastructure and Accelerator Research Area) project funded by the European Union 7th framework programme made a survey of provision of education and training in accelerator science in Europe highlighted the need for more training opportunities targeting undergraduate-level students. This need is now being addressed by the European Union H2020 project ARIES (Accelerator Research and Innovation for European Science and Society) via the preparation of a Massive Online Open Course (MOOC) on particle accelerator science and engineering. We present here the current status of this project, the main elements of the syllabus, how it will be delivered, and the schedule for providing the course.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-MOPML050  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAL013 Design of the Diagnostic Stations for the ELI-NP Compton Gamma Source 2173
SUSPF103   use link to see paper's listing under its alternate paper code  
 
  • M. Marongiu
    INFN-Roma, Roma, Italy
  • M. Castellano, E. Chiadroni, G. Di Pirro, G. Franzini, A. Giribono, V. Shpakov, A. Stella, A. Variola
    INFN/LNF, Frascati (Roma), Italy
  • A. Cianchi
    Università di Roma II Tor Vergata, Roma, Italy
  • A. Mostacci, L. Palumbo
    Sapienza University of Rome, Rome, Italy
 
  A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches, 16 ns spaced, with a nominal charge of 250 pC will collide with the laser beam in the interaction point. Electron beam spot size is measured with optical transition radiation (OTR) profile monitors. Furthermore, OTR angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor beam envelope, one may perform a distributed energy measurement along the machine. This will be useful, for instance, during the commissioning phase of the GBS in order to verify the correct functionality of the C-Band accelerating structures, due to the fact that there are OTR screens after each accelerating module. This paper deals with the studies of different optic configurations to achieve the field of view, resolution and accuracy in order to measure the energy of the beam. Several configurations of the optical detection line will be studied with simulation tools (e.g. Zemax).  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL013  