Author: Chiu, M.-S.
Paper Title Page
WEPAL062 Bunch Length Measurements with a Streak Camera in Low Alpha Lattice Operation at the TPS 2316
 
  • C.H. Chen, J.Y. Chen, M.-S. Chiu, P.J. Chou, K.T. Hsu, K.H. Hu, C.-C. Kuo, C.C. Liang, C.Y. Liao, Y.-C. Liu, G.-H. Luo, H.-J. Tsai, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  We developed and tested lattice with lower momentum compaction factor (low alpha) in TPS (Taiwan Photon Source) recently. Operating low alpha lattice can provide picosecond bunch length for time-resolved research and coherent IR/THz synchrotron light. The bunch length around 2.5 picosecond rms was measured by a streak camera* in low alpha mode while operating in the routine users mode** it was around 10 picosecond. This paper presents the related processes and measurements.
* L.Y. Liao et al., "Preliminary beam test of synchrotron radiation monitoring system at Taiwan Photon Source", IPAC'15.
** C.C. Kuo et al., "Commissioning of Taiwan Photon Source", IPAC'15.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL062  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAK053 Side Effects of Local Bump in TPS Storage Ring 3340
 
  • M.-S. Chiu, C.H. Chen, J.Y. Chen, P.J. Chou, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) is a low-emittance 3-GeV light source at National Synchrotron Radiation Research Center. Five in-vacuum undulator beamlines were delivered to users on Sep. 22, 2016. Another 2 EPU beamlines will be open to user in near future. In the beginning, the local bump was used to do ID spectrum optimization since 2016. After this procedure, the ID spectrum are consistent between theoretical simulation and measurement. Recently, we found the local bump will cause tune shift and orbit distortion. In this paper, we will present the effect of local bump in TPS.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK053  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMK012 Reduction of Dynamic Multipole Content in Insertion Devices Using Flat Wires 4313
 
  • T.Y. Chung, S.D. Chen, M.-S. Chiu, S.J. Huang, C.-S. Hwang, J.C. Jan, C.Y. Kuo, Y.T. Li, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
  • C.-S. Hwang
    NCTU, Hsinchu, Taiwan
 
  Multipole errors of an insertion device are generally corrected based on measurements and analysis of the magnetic field integrals. Multipole components in a strong and narrow non-uniform field of an insertion device appear as dynamic multipoles. Flat wires were installed and commissioned to determine if the dynamic multipoles can be eliminated in an APPLE-II type undulator. In this work, we will discuss and compare the reduction of the dynamic multipole content and it's beam dynamics effects with the flat wire through an analysis of field calculations and beam-based measurements in the storage ring.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPMK012  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)