Author: Chan, C.K.
Paper Title Page
THPAK055 Suppression of Transverse Beam Instabilities by Stripline Kickers at TPS 3346
 
  • P.J. Chou, C.K. Chan, C.-C. Chang, K.T. Hsu, K.H. Hu, C.K. Kuan, I.C. Sheng, F.H. Tseng
    NSRRC, Hsinchu, Taiwan
 
  Collective beam instabilities could limit the accelerator performance if proper countermeasures are not in place. Active beam feedback systems are commonly used to suppress beam instabilities. The resistive wall impedance including phase-II insertion devices at TPS are calculated with analytical formulas. The growth rate of transverse coupled bunch instabilities due to wall impedance is estimated by theory. The RF properties of existing stripline kickers in TPS are analyzed with a 3-D electromagnetic simulation code GdfidL. Based on the above analysis, the requirements for a beam feedback system are calculated and the results are reported.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK055  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL056 Vibration Measurements in the TPS Vacuum System 3772
 
  • Y.C. Yang, C.K. Chan, C.-C. Chang, C.S. Chen, J. -Y. Chuang, Y.M. Hsiao, C.C. Liang, Y.Z. Lin
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) is currently operated in top-up mode for users. In order to improve the stability of the synchrotron light source, vibrations related to the vacuum system have been investigated and improved by turning off pumping systems and reducing the flow rate in chamber cooling water circuits. In this paper, vibrations in different vacuum chambers with normal cooling water condition were investigated, their sources were recorded and clarified and properties of different materials for water tubes were also compared.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL056  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL058 Effect of Ozonated Water Cleaning on Photon Stimulated Desorption in a Stainless Steel Chamber 3778
 
  • C.M. Cheng, C.K. Chan, C.-C. Chang, Y.T. Cheng, J. -Y. Chuang, G.-Y. Hsiung, L.H. Wu, Y.C. Yang
    NSRRC, Hsinchu, Taiwan
 
  Aluminium vacuum chambers cleaned with ozonated water show a reduction of residual carbon and lower surface outgassing rate after baking. We would like to investigate if stainless steel chambers show similar ef-fects. A stainless steel test chamber was cleaned by stand-ard chemical cleaning only and then compared with an-other one after immersion in 30ppm ozonated water for thirty minutes. Both samples were baked, then photon exposed and the photon desorption yields were deter-mined by vacuum gauges and residual gas analysers at the TLS 19B beamline. The test results on photon stimulated desorption yields and partial pressure variations with and without ozonated water cleaning of the stainless steel tubes will be discussed in some detail.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL058  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)