Author: Akagi, T.
Paper Title Page
THPAK019 Beam Dynamics of the First Beams for IFMIF-EVEDA RFQ Commissioning 3246
 
  • L. Bellan, C. Baltador, M. Comunian, E. Fagotti, F. Grespan, A. Pisent
    INFN/LNL, Legnaro (PD), Italy
  • T. Akagi
    KEK, Ibaraki, Japan
  • B. Bolzon, N. Chauvin
    CEA/DSM/IRFU, France
  • H. Dzitko
    F4E, Germany
  • K. Kondo, M. Sugimoto
    QST, Aomori, Japan
  • I. Podadera
    CIEMAT, Madrid, Spain
  • F. Scantamburlo
    IFMIF/EVEDA, Rokkasho, Japan
 
  The installation of the IFMIF-EVEDA RFQ, MEBT, LEBT, source and beam dump was completed in September 2017. The beam dynamics of the first beams for the IFMIF-EVEDA RFQ commissioning is presented. Moreover, a proposal for the CW RFQ steady state commissioning is shown, with a focus on the beam dynamics challenges of the beam transport after the RFQ.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAK019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAF026 Beam Induced Fluorescence Measurements of 100 keV Deuterons in LIPAc Accelerator 1877
SUSPL052   use link to see paper's listing under its alternate paper code  
 
  • R. Varela, A. Guirao, L.M. Martínez, J. Mollá, I. Podadera
    CIEMAT, Madrid, Spain
  • T. Akagi, R. Ichimiya, Y. Ikeda, M. Sugimoto
    QST, Aomori, Japan
  • B. Bolzon, N. Chauvin
    CEA/IRFU, Gif-sur-Yvette, France
  • P. Cara
    Fusion for Energy, Garching, Germany
  • H. Dzitko
    F4E, Germany
  • J. Knaster
    IFMIF/EVEDA, Rokkasho, Japan
 
  Funding: Work partially supported by the Spanish Ministry of Science and Innovation under project FIS2013-40860-R
The LIPAc accelerator will be a linear CW deuteron accelerator capable of delivering a 9 MeV, 125 mA beam which aims to validate the technology that will be used in the future high power accelerator-driven neutron source, IFMIF. In summer 2017 a campaign of measurements was done during the injector commissioning, in which a Fluorescence Profile Monitor based on an Intensified CID camera (ICID) was used to measure the beam transverse profile at the extraction of the ion source. In this contribution we review the design of the ICID, its performance and discuss the measurements carried out. The performance of ICID monitors for its use in future accelerators will be assessed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAF026  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)