During the last 2.5 years, MAX IV have installed and commissioned in total 15 insertion devices out of which 6 are new in vacuum undulators, 1 in vacuum wiggler, and 7 in-house developed and manufactured Apple II elliptical polarized undulators. From the old lab, MAXLAB, 1 PU is also reused. Looking forward, 3 additional insertion devices will be installed shortly. As MAX IV only has one Control and IT group, the same concept of machine and beamline installation have been applied also to the insertion devices, i.e. Sardana, Tango, PLC, and IcePAP integration. This has made a seamless integration possible to the rest of the facility in terms of user interfaces, alarm handling, archiving of status, and also future maintenance support.
|
|
|