JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


BiBTeX citation export for WEPHA136: The Software-Based Machine Protection System Using EPICS in J-PARC MR

@InProceedings{sato:icalepcs2019-wepha136,
  author       = {K.C. Sato and N. Kamikubota and T. Kimura and S. Yamada and N. Yamamoto and S.Y. Yoshida},
  title        = {{The Software-Based Machine Protection System Using EPICS in J-PARC MR}},
  booktitle    = {Proc. ICALEPCS'19},
  pages        = {1418--1420},
  paper        = {WEPHA136},
  language     = {english},
  keywords     = {EPICS, operation, controls, GUI, status},
  venue        = {New York, NY, USA},
  series       = {International Conference on Accelerator and Large Experimental Physics Control Systems},
  number       = {17},
  publisher    = {JACoW Publishing, Geneva, Switzerland},
  month        = {08},
  year         = {2020},
  issn         = {2226-0358},
  isbn         = {978-3-95450-209-7},
  doi          = {10.18429/JACoW-ICALEPCS2019-WEPHA136},
  url          = {https://jacow.org/icalepcs2019/papers/wepha136.pdf},
  note         = {https://doi.org/10.18429/JACoW-ICALEPCS2019-WEPHA136},
  abstract     = {In J-PARC, a Machine Protection System (MPS) stops accelerator beam operation automatically when an interlock signal comes. Normal MPS accepts interlock signals by hard-wire, but a software-based MPS, called "Soft-MPS", uses only EPICS PVs without wiring. A PLC controller running Linux was introduced to watch at some EPICS PVs over Ethernet, and outputs Soft-MPS signals to the MPS unit after logical calculates. There are 2 reasons of using Soft-MPS. (1) To install interlock signals rapidly. This type of Soft-MPS will switch to hard-wire later. (2) To use non-hardware parameters: for example, machine operation modes, beam bunch information, etc. From the first Soft-MPS setup in 2018 spring, 9 Soft-MPS signals are currently used. As more Soft-MPS signals are expected in the future, we need to discuss the policy.},
}