J. Chen, S.S. Cao, F.Z. Chen, B. Gao, L.W. Lai, Y.B. Leng, T. Wu, X.Y. Xu, R.X. Yuan, Y.M. Zhou
SSRF, Shanghai, People’s Republic of China
Precise bunch charge measurement is the fundamental of charge feedback, beam lifetime measurement, beam loss monitor, as well as the basis of the related interlocking work. Beam position monitor (BPM) is often used for high-precision bunch charge measurement due to its superior performance. In this paper, the pros and cons of different types of BPM for measurement of bunch charge in storage ring and free electron laser (FEL) will be discussed. The related simulations, beam experiment and signal processing methods are also mentioned. The beam experiments results show that the relative bunch charge resolution of the Button BPM can reach 0.02% in SSRF, 0.073% and 0.021% of the SBPM and CBPM in SXFEL, respectively. Besides, based on the method of beam experiments, we systematically studied the position dependence of BPM pickup and related compensation algorithms for high-precision bunch charge measurement.