Author: Johansen, E.
Paper Title Page
WEPP33 Progress of Profile Measurement Refurbishment Activities at HIPA 179
 
  • R. Dölling, E. Johansen, M. Roggli, M. Rohrer
    PSI, Villigen PSI, Switzerland
 
  At PSI’s High Intensity Proton Accelerator (HIPA) facility some 180 profile monitors and 10 radial probes are in use to measure transverse beam profiles in beam lines and cyclotrons at energies of 0.87 to 590 MeV. Mechanical malfunctions and increased noise in some devices, a lack of spare parts and the obsolescence of most of the driver and read-out electronics as well as extended requirements to the measurement, necessitate the development of improved versions of the electronics and of several monitors. We give an update on the status of three projects in this regard: A long radial probe in the Ring Cyclotron, a profile monitor and BPM at 590 MeV in high radiation environment and new loss monitor electronics, which should also serve as a basis for the profile monitor readout.  
poster icon Poster WEPP33 [2.752 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2020-WEPP33  
About • paper received ※ 10 September 2020       paper accepted ※ 15 September 2020       issue date ※ 30 October 2020  