Author: Decker, G.
Paper Title Page
TUAO02 Diagnostics for Collimator Irradiation Studies in the Advanced Photon Source Storage Ring 26
 
  • J.C. Dooling, W. Berg, M. Borland, J.R. Calvey, G. Decker, L. Emery, K.C. Harkay, R.R. Lindberg, A.H. Lumpkin, G. Navrotski, V. Sajaev, J.B. Stevens, Y.P. Sun, K.P. Wootton, A. Xiao
    ANL, Lemont, Illinois, USA
 
  Funding: Work supported by the U.S. D.O.E.,Office of Science, Office of Basic Energy Sciences, under contract number DE-AC02- 06CH11357
The Advanced Photon Source (APS) is building a fourth-generation storage ring (4GSR), replacing the present double-bend achromat lattice with a multibend achromat system thereby allowing the production of ultra-bright x-ray beams. The new lattice enables a two-order-of-magnitude reduction in horizontal beam emittance and a factor of two increase in beam current. The result is an electron beam of very high energy- and power-densities. Initial predictions suggest virtually any material struck by the undiluted electron beam will be damaged. Two experimental beam abort studies have been conducted on collimator test pieces in the present APS SR to inform the design of a fully-functional machine protection system for APS 4GSR operations at 200 mA. A comprehensive suite of diagnostics were employed during the studies The diagnostics used in these experiments are not new, but employed in different ways to obtain unique data sets. With these data sets now in hand, we are developing new numerical tools to guide collimator design.
 
video icon
        Right click on video for
Picture-in-Picture mode
or Full screen display.

At start the sound is muted!
 
slides icon Slides TUAO02 [26.053 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2020-TUAO02  
About • paper received ※ 03 September 2020       paper accepted ※ 15 September 2020       issue date ※ 30 October 2020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPP05 X-Ray Beam Size Monitor Enclosure for the Advanced Photon Source Upgrade 34
 
  • K.P. Wootton, W.X. Cheng, G. Decker, S.H. Lee, B.X. Yang
    ANL, Lemont, Illinois, USA
 
  Funding: This research used resources of the Advanced Photon Source, operated for the U.S. Department of Energy Office of Science by Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
Confirmation of pm rad scale emittances from the Advanced Photon Source Upgrade electron storage ring necessitates direct measurement of the electron beam size. In the present work, we motivate design choices for the X-ray beam size monitor shielding enclosure for the Advanced Photon Source Upgrade. Particular emphasis is given to outlining design choices from the perspectives of safety, overall project construction schedule and eventual beamline operations.
 
poster icon Poster TUPP05 [0.609 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2020-TUPP05  
About • paper received ※ 02 September 2020       paper accepted ※ 14 September 2020       issue date ※ 30 October 2020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)