Keyword: acceleration
Paper Title Other Keywords Page
MOPP003 Beam Current Measurements with Sub-Microampere Resolution using CWCT and BCM-CW-E linac, instrumentation, electronics, electron 63
 
  • F. Stulle, L. Dupuy, E.T. Touzain
    BERGOZ Instrumentation, Saint Genis Pouilly, France
  • W.A. Barth, P. Forck, M. Miski-Oglu, T. Sieber
    GSI, Darmstadt, Germany
 
  The CWCT current transformer and its accompanying BCM-CW-E electronics allow accurate, high-resolution beam current measurements. This is achieved by combining a high-droop current transformer with low-noise sample-and-hold electronics. Thanks to a fast response time on the microseconds level the system can be applied not only to CW beams but also macropulses. Pulse repetition rates may range from 10MHz to 500MHz, rendering CWCT and BCM-CW-E suitable for a wide variety of accelerators. We report on test bench measurements achieving sub-microampere resolution. And we discuss results of beam measurements performed at the cwLINAC (GSI), which confirm the expected performance.  
poster icon Poster MOPP003 [6.507 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP003  
About • paper received ※ 04 September 2019       paper accepted ※ 08 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPP027 First Beam-based Test of Fast Closed Orbit Feedback System at GSI SIS18 controls, feedback, closed-orbit, synchrotron 154
 
  • R. Singh, A. Doring, P. Forck, K. Lang, S.H. Mirza, D. Rodomonti, D. Schupp, M. Schwickert, H. Welker
    GSI, Darmstadt, Germany
  • A. Bardorfer
    I-Tech, Solkan, Slovenia
 
  Funding: European Unions Horizon 2020 Research and Innovation programme under Grant Agreement No. 730871 (ARIES). German Academic Exchange Service under Personal Reference No. 91605207.
The SIS18 synchrotron of GSI will be used as a booster ring for the SIS100 synchrotron built in the scope of the FAIR project. In order to preserve the beam quality during the whole acceleration ramp, a new closed orbit feedback (COFB) system is implemented at the SIS18 which operates with the existing BPMs and steerer magnets. The system aims for a bandwidth of several 100 Hz and robustness against the variation of the response matrix and the beam rigidity during the ramp. The architecture of the system and the results of the first beam-based test of the COFB hardware are presented. As a first step, the orbit correction is performed over the entire ramp using the response matrix corresponding to injection energy only taking the beam rigidity into account. Experimental observations of the bandwidth limitations arising from the temporal delay of the steerer power supplies and the spatial model variation during the ramp are compared with simulations. It is found that the temporal and the spatial model mismatch have similar effect on the achievable bandwidth of the COFB.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP027  
About • paper received ※ 07 September 2019       paper accepted ※ 08 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)