Paper | Title | Page |
---|---|---|
TUPP047 | Ionization Profile Monitor Design and Experiments in HIRFL-CSR | 444 |
|
||
Funding: Supported by the National Natural Science Foundation of China (Nos. 11805250 To meet the needs of real-time profile monitoring, injection match optimization, transverse cooling mechanism research in Cooling Storage Ring of Heavy Ion Research Facility of Lanzhou (HIRFL-CSR), and the profile measurement of future intense facilities like High Intensity Heavy-ion Accelerator Facility (HIAF) and China Initiative Accelerator Driven System (CiADS) in Huizhou China, some IPM research and experiments has been proceed since 2013. In 2016, the first IPM was developed with MCPs, phosphor screen and camera acquisition system for vertical profile monitoring in HIRFL-CSRm. Then another horizontal IPM with new framework and less field distortion was also deployed in CSRm at 2018 summer. Besides, two more IPMs will be installed in HIRFL-CSRe during next summer maintenance. This paper mainly presents the horizontal IPM design concerns, HV settings influence, some experiment anomalies, as well as experiments for transverse electron cooling and normal operation mode orbit variation at HIRFL-CSR in December 2018. |
||
Poster TUPP047 [1.532 MB] | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-TUPP047 | |
About • | paper received ※ 04 September 2019 paper accepted ※ 09 September 2019 issue date ※ 10 November 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |