Author: Wang, Q.
Paper Title Page
WEPP022 A Method of Correcting the Beam Transverse Offset for the Cavity Bunch Length Monitor 572
 
  • Q. Wang, Q. Luo, B.G. Sun
    USTC/NSRL, Hefei, Anhui, People’s Republic of China
 
  Funding: Supported by National Key R&D Program of China (Grant No. 2016YFA0401900 and No. 2016YFA0401903) and The National Natural Science Foundation of China (Grant No. U1832169 and No. 11575181)
Cavity bunch length monitor uses monopole modes excited by bunches within the cavities to measure the bunch longitudinal root mean square (rms) length. It can provide a very high accuracy and high resolution. However, when the bunch passes through the cavities with transverse offset (that is, the bunch moves off the cavity axis), the amplitude of the monopole modes will change and cannot reflect the bunch length precisely. In this paper, a method of correcting the beam transverse offset is proposed. Simulation results show that the method can reduce the error of the bunch length measurement significantly.
 
poster icon Poster WEPP022 [0.735 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-WEPP022  
About • paper received ※ 03 September 2019       paper accepted ※ 10 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)