Author: Schmidt-Foehre, F.    [Schmidt-Föhre, F.]
Paper Title Page
MOPP019 Development and Evaluation of an Alternative Sensor Lifetime Enhancement Technique Used with the Online-Radiation-Monitoring System (DosiMon) at the European XFEL at DESY, Hamburg 122
 
  • F. Schmidt-Föhre, S. Arab, D. Nölle, R. Susen
    DESY, Hamburg, Germany
 
  The European XFEL (E-XFEL), that started operation in September 2017 at the DESY/XFEL site in Hamburg/Germany uses a single-tunnel concept, forcing all frontend machine devices and electronics to be located inside the accelerator tunnel. Electro-magnetic showers, mainly produced by gun dark-current, RF cavity field-emission and beam-losses expose these devices to damaging irradiation. The new Online-Radiation-Monitoring-System (DosiMon) is mainly used for surveillance of radiation sensitive permanent magnet structures, diagnostic devices and rack-housed electronics. The integrated dose from Gamma- and optional future Neutron-radiation measurements can be monitored online by the DosiMon system. Safety limits ensure the correct function of monitored devices, provided by lifecycle estimations as measures for on time part exchange, to prevent significant radiation damage. A first expansion state currently enables more than 500 gamma measuring points. The development of a new sensor lifetime enhancement technique for the utilized RadFet sensors is presented together with corresponding evaluation measurements.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP019  
About • paper received ※ 04 September 2019       paper accepted ※ 08 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPP005 BPM Resolution Studies at PETRA III 517
 
  • G. Kube, J. Neugebauer, F. Schmidt-Föhre
    DESY, Hamburg, Germany
 
  In order to measure the noise level of a BPM system from beam generated orbit data, the correlated beam jitter has to be removed from the position signals. There exist different ways to extract the BPM noise, as the "three-BPM" correlation method or the model-independent principal components analysis (PCA). Both methods will shortly be reviewed. Based on a PCA, the resolution of the PETRA III Libera Brilliance based BPM system was measured. The results will be presented together with first measurements in view of an updated BPM system for the future PETRA IV project at DESY.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-WEPP005  
About • paper received ※ 02 September 2019       paper accepted ※ 10 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)