Author: Ptaszkiewicz, M.
Paper Title Page
TUPP026 Diagnostic Beamlines at the Solaris Storage Ring 366
 
  • A. Kisiel, S. Cabala, A.M. Marendziak, M. Ptaszkiewicz, A.I. Wawrzyniak, I.S. Zadworny, Z. Zbylut
    NSRC SOLARIS, Kraków, Poland
 
  Precise measurement and control of the particle beam emittance is a very important input to characterize the performance of any accelerator/SRS. Beam characterizations at the SOLARIS National Synchrotron Radiation Centre are provided by two independent diagnostic beamlines called the X-ray synchrotron radiation (PINHOLE) and optical synchrotron radiation (LUMOS) beamlines, respectively. The PINHOLE beamline depicts the electron beam by analyzing the emitted X-rays. However this method is predominantly applied to the middle and high energy storage rings. At Solaris storage ring with the nominal energy of 1.5 GeV and critical photon beam energy of c.a. 2 keV, the design of the beamline was modified to provide sufficient X-ray photon flux for proper imaging. Second diagnostic beamline LUMOS will be installed and commissioned in next few months. Issues discussed include the general design philosophy, choice of instrumentation, limits to resolution, and actual performance.
*e-mail: adriana.wawrzyniak@uj.edu.pl
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-TUPP026  
About • paper received ※ 04 September 2019       paper accepted ※ 09 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)