Paper | Title | Page |
---|---|---|
WEPP009 |
Measurement of Electron Pulse Length at 35 MeV Using a Terahertz Split Ring Resonator | |
|
||
Funding: This work was supported by the European Union’s Horizon 2020 Research and Innovation Programme (730871). X.Y. Liu was supported by China Scholarship Council for a 2-year study at PSI (201706340057). The resolution of a streak camera system strongly depends on the slew rate of the deflecting element, which is the product of the amplitude and frequency of the device. An attractive approach towards femtosecond and sub-femtosecond range consists in using terahertz-driven devices, which offer a good combination of high frequency and high gradient-gradients of GV/m have been demonstrated in split ring resonator using pulse created by rectifying ultrashort laser pulses. We present results obtained from a beam experiment at the VELA facility at Daresbury laboratory. We tested a planar resonator derived from the geometry of a split ring resonator with an aperture for the beam of 20 um. Email address: xiaoyu.liu@psi.ch |
||
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |